Roof Framing: Trusses, Rafters, and the Structural Role of Your Roof

One morning in February, you notice a thin crack in the corner of the living room ceiling, and the bedroom door has been rubbing against the frame ever since the last major siding job. The roof framing is the wooden structure (prefabricated trusses or rafters and joists) that supports the roof, bears the weight of winter and the wind, and transfers these loads to the supports.

Key Points

  • The roof structure determines what can be done on the roof and in the attic, even though it’s almost never visible.
  • There are two main types in Quebec: prefabricated roof trusses and traditional roof framing.
  • A truss must not be cut, drilled, or notched without an engineer’s calculation.
  • A typical roof in Montreal is designed to withstand approximately 1.47 kPa of snow and rain load.
  • Cracks, doors that stick, and creaking noises warrant an on-site inspection.

What is the purpose of a roof truss?

The roof frame forms the skeleton of the roof, regardless of the materials used to cover it: shingles, sheet metal, roofing membrane, or tiles. It supports the decking (the layer of boards or panels to which the shingles, metal sheeting, or tiles are attached), the weight of winter, rain, and wind pressure. It then distributes these forces to the wall plates and load-bearing walls, and ultimately to the foundation. Its strength depends on each of its components and how they are joined together.

When the wood warps, everything resting on it follows suit: the membrane, the shingles, the ceiling, and sometimes the walls. Problems rarely all appear at the same time. Repairing a roof on weakened structural elements therefore does not solve the problem in the long run. That’s why replacing a residential roof begins with an inspection of the framing.

Prefabricated roof trusses with their temporary bracing.

Prefabricated roof trusses with their temporary bracing.

Prefabricated roof trusses or rafters: the two types of roof framing in Quebec

The roof truss system

A roof truss is a factory-made triangular truss. Its top chord follows the slope, its bottom chord forms the ceiling, and the web (the diagonals between the two) is assembled using metal connectors—small serrated steel plates. This structure spans large distances using very little wood. Its attic space is filled with diagonal braces and cannot be converted into living space.

The CSA S349:20 standard establishes quality control requirements for the manufacture of trusses and beams with metal connectors. Published in September 2020, it is not yet required by the Régie du bâtiment. Certified member factories of the Quebec Wood Structure Manufacturers Association undergo two independent inspections per year.

Traditional rafter framing

In traditional roof framing, the rafters (slanted pieces of wood that support the decking) rest on the wall plate and meet at the ridge. The ceiling joists connect the two sides of the house. This construction creates a convertible attic space and allows for a cathedral ceiling, where the ceiling follows the slope of the roof. It is found primarily in older homes and multi-unit buildings in established neighborhoods.

The components of a gable roof.

The components of a gable roof.

Roof framing terminology explained simply

  • Rafter: a crossbeam that connects the base of two roof slopes and prevents the house from spreading apart.
  • False stringer: a crossbeam placed higher up that reduces the span of the roof slopes.
  • Rafter and strut: vertical or diagonal members that transfer the load to a support.
  • Wall plate: a beam placed at the top of the wall, on which the roof framing rests.
  • Ridge board: a board placed at the ridge, where the two roof slopes meet.
  • Hip beam and valley rafter: slanted timbers at the projecting and recessed corners where two roof slopes meet.

These elements are found in both types of roof frames, though with different joints and techniques. Depending on the type of roof, the main horizontal beam or the wall plates take on different roles.

Purlins, rafters, and beams: a detailed look at traditional roof framing

In a traditional purlin roof structure, the rafters are the long, sloping timbers of a solid-wood truss, held in place by a rafter head and struts. They support the purlins, which are horizontal beams laid across the slope. The ridge purlin runs along the top of the roof, while the wall plate runs along the foot of the slope, against the wall. The rafters then rest on these purlins.

This type of joint, more common in Europe and in historic buildings, is rarely seen in newer Quebec homes, where trusses have largely replaced it. It can be found in some barns, country houses, and older buildings. Its stability depends on the quality of the joints and the condition of each beam. A split member or a beam that has absorbed water alters the load distribution throughout the entire structure.

These techniques require a carpenter who is familiar with the materials and best practices. The first step in a renovation project for this type of roof remains the same: have the condition of the wood assessed before choosing the roofing material.

Code Requirements for Roof Framing

The current version is the Quebec Construction Code, Building Chapter, which incorporates the 2020 National Building Code with Quebec-specific amendments. It has been in effect since April 17, 2025. The requirements of Part 9 regarding roof framing can be summarized as follows:

  • Minimum support of 38 mm at the ends of joists or rafters.
  • Opposite rafters paired in twos and joined at the ridge, notched at the supports to provide a flat contact surface.
  • Hip rafters and valley rafters must be at least 50 mm higher than standard rafters, with an actual thickness of at least 38 mm.
  • Paired members at the edges of an opening wider than two spacings, for a skylight, dormer, or chimney.
  • 3 kN wind-liftconnectors where wind pressure reaches 0.8 kPa or higher.

A stringer or joist measuring 38 x 89 mm or larger may be used as an intermediate support if the slope is 1:3 (4/12) or steeper. A stringer longer than 2.4 m must be supported laterally near its center. Braces and struts must be at least 38 x 89 mm and form an angle of at least 45 degrees with the horizontal plane. Wood trusses are designed in accordance with the calculation procedures of the Canadian Institute of Metal-Connected Roof Trusses, and their bracing must conform to the design drawings. The full text can be found at LégisQuébec.

Can a roof truss be modified to convert the attic?

No, not without an engineering analysis. The Code prohibits cutting, drilling, or weakening any truss component unless this weakening is accounted for in the calculations. Cutting a diagonal brace to create a passageway or drilling a hole in a member for a duct removes wood from a component that has been designed to the absolute minimum.

Trusses form a system in which each component works in conjunction with the others, and their stability comes from this interplay. A single cut shifts the loads to parts that were not designed to bear them. The structural engineer can then design a reinforcement or another solution, supported by drawings.

Snow, Wind, and Humidity

Traditional rafter roof structure in the attic of a Plex.

Snow, wind, and moisture: what takes a toll on a roof structure

Snow

In Montreal, the Code specifies a ground snow load of 2.6 kPa and a rain load of 0.4 kPa. The base load for a standard roof is approximately 1.47 kPa (S = 0.55 Ss + Sr). Exceptional accumulations, ice, and snowdrifts blown by the wind against a dormer window can sometimes exceed these calculations. Our article on snow loads on roofs explains these concepts in detail.

Wind

The wind lifts the roof slopes as much as it pushes against them. The connectors between the roof and the wall hold the structure in place against this lifting force.

Moisture in the attic

Warm air from the house rises into the attic, condenses on the cold wood, and eventually causes it to rot. Water seeping through the roof has the same effect, but in a more localized area: moisture penetrates the wood and weakens it. The Code requires a ventilated space between the insulation and the roof sheathing. The total open area of the vents must be at least 1/300 of the surface area of the insulated ceiling, and 1/150 if the roof slope is less than 1:6 or if the roof has joists. This area is distributed between the top and bottom of the roof. Poor attic ventilation leads to the mold in the attic, and then wood that loses its strength.

Signs of a Weakening Roof Structure

A sagging ridge or a wavy roof can be seen from the street at the end of the day, when the sun is low. Inside, the Régie du bâtiment points out these signs:

These include cracks in interior walls, interior doors that stick or scrape, unusual creaking noises, and a warped ceiling. Visible moisture or mold in the attic completes the picture.

If there are many of these signs, you should evacuate the building and have the roof cleared. Even a single one of these signs warrants an inspection, as the cause may also be settlement of the foundation.

What the roofer checks during a roof repair

Structural problems are often discovered at this stage. Removing the old siding exposes the decking. Here, we inspect the boards or panels for signs of discoloration, softening, or delamination, check the alignment of the trusses or framing, and look for cracks in the supports and on the underside of the decking. We also inspect the connectors, bracing, and openings for chimneys or skylights.

Damaged decking is replaced before installation. We call in a structural engineer when wood is split, cut through, or rotten; when a truss has been modified; or after major changes to the house. A pre-construction roof inspection helps identify these issues early on. The assessment is free during business hours and includes a photo report within 24 to 48 hours. For emergencies, our service is available 24 hours a day, 7 days a week.

Frequently Asked Questions About Roof Framing

How can I tell if my roof has trusses or rafters?

Go up to the attic with a flashlight. A network of diagonal triangular braces indicates trusses. An open space beneath large sloping beams indicates a traditional roof frame.

With a traditional roof structure, the answer is often yes, depending on the height, the supports, and the humidity in the attic. This is the first issue to address before starting the project. With trusses, an engineering analysis is required before any modifications are made.

It is a board or slat that prevents trusses from tipping over during and after installation. According to the Quebec Wood Structure Manufacturers Association, the absence of temporary bracing or errors in its installation is the leading cause of accidents during installation. Their guide is not a substitute for an engineer.

Not always. An isolated crack is often caused by wood shrinkage or the finish. Multiple cracks accompanied by doors that stick require a prompt inspection.

An engineer is required for any modification to a truss, for any visible sagging, and after an exceptional accumulation of weight on the roof. An engineer is also required after an expansion or a major renovation.

Free quote with no obligation